Maxiclad® Installation Information

Maxiclad Fixing and Laying Directions - Non-Cyclonic Areas

Note: The following recommendations apply to non-cyclonic areas.

• Sheets should be laid into the prevailing weather as shown to reduce the possibility of penetration of wind driven rain.
• Pan fixing - one fixing required per pan. Fasten adjacent to overlapping rib.
• Crest fixing - one fixing required per crest.
• The below fastener sizes are suitable for fixing over an insulation blanket up to 55mm thick. For thicknesses up to 100mm, the next standard screw length to that indicated is to be used.
Maxiclad Fastener Selection
  Walling
Crest Fixing Pan Fixing
Fixing to Steel
Self drilling and tapping screw with neoprene washer

12 x 35mm

10 x 16mm
Fixing to Timber
Type 17 hex head screw with neoprene washer

12 x 50mm

10 x 25mm
Laying Procedure