Profile

Material Specifications
| Material Specifications | ||||||
| Material Properties | 0.35mm BMT | 0.42mm BMT | 0.48mm BMT | |||
| Zinc/alum | Colour | Zinc/alum | Colour | Zinc/alum | Colour | |
| Total Coated Thickness (mm) | 0.40 | 0.43 | 0.47 | 0.50 | 0.53 | 0.56 |
| Mass (kg/linear metre) | 2.74 | 2.79 | 3.26 | 3.32 | 3.70 | 3.76 |
| Mass (kg/square metre) | 4.22 | 4.29 | 5.02 | 5.11 | 5.69 | 5.78 |
| Yield (square metre tonne) | 237.0 | 233.1 | 199.2 | 195.7 | 175.7 | 173.0 |
| Tensile Strength (MPa) | G550 | G550 | G550 | G550 | G550 | G550 |
| Width Coverage (mm) | 650 | 650 | 650 | 650 | 650 | 650 |
| Sheet Tolerances (mm) Length & Width | ±5 ±2 | ±5 ±2 | ±5 ±2 | ±5 ±2 | ±5 ±2 | ±5 ±2 |
| Minimum Roof Pitch | N/A | N/A | 1° | 1° | 1° | 1° |
Design considerations
The minimum recommended roof pitch for Prodek is one degree (1 in 60). With a one degree fall, ensure that building settlement or the warping of timber structural sections does not cause ‘ponding' on the surface of the roof. The 650mm coverage of Prodek provides easy handling and installation. Prodek roofing is subject to thermal expansion, particularly on darker colours. The maximum length before an expansion joint is required is 24 metres for lighter colours, and 16 metres for darker colours.
Compliance
The Wind Capacity Tables are based on testing in accordance with AS1562.1-1992 and AS4040.0, 1 & 2- 1992. Span tables have been developed by determining wind pressures in accordance with AS4055-2006 for domestic applications and AS/NZS 1170.2:2002 for all other applications. Capacity tables are in limit state format.
Spans
Spans are determined by wind speeds for non-cyclonic areas. For domestic applications, the pressures and spans are based on a maximum: eaves height of six metres, roof pitch of 35 degrees and total roof height of 8.5 metres. For commercial and industrial applications, tables are based on a maximum overall height of ten metres and a 500 year design return period.
Roofing calculations are based on Cpe=-0.9 and Cpi=0.2, walling is based on Cpe=-0.65 and Cpi=0.2. A local pressure factor, Kl=2.0 has been used for all roofing and walling spans for both strength and serviceability limit states. Roof spans allow for loads incidental to maintenance.
All pressures have been determined assuming the wind loading in any direction is not affected by topography. The following shielding factors have been used for each of the terrain categories: Category 3 = 0.85, Category 2.5 = 0.95, and Category 2 = 1.
The carport and verandah spans only apply to structures not enclosed by peripheral walls. Spans are based on Cpn=-0.9 and Kl=1.5 applied over the entire span, and are suitable for all span types. Loads on supporting purlins may limit these spans.
Stratco can provide additional engineering advice if any design parameters vary from those above.

Maximum Recommended Spans (mm)
| Maximum Recommended spans | ||||||
| Span Type | Roofing BMT | Walling BMT | ||||
| 0.42mm | 0.48mm | 0.35mm | 0.42mm | 0.48mm | ||
| Single Span | 2600 | 3100 | 2400 | 3000 | 3600 | |
| End Span | 2800 | 3400 | 2700 | 3500 | 4000 | |
| Internal Span | 3200 | 3800 | 3000 | 3800 | 4200 | |
| Unstiffened Overhang | 200 | 250 | 150 | 200 | 250 | |
| Stiffened Overhang | 600 | 650 | 400 | 600 | 650 | |
| Roofing : Spans are limited based on typical maintenance foot traffic. Walling : Spans based on N1 (W28) wind loading. |
||||||
| Domestic Carport / Verandah Spans (mm) | ||||
| Wind Classification | Base Metal Thickness | |||
| 0.42mm | 0.48mm | |||
| N1 (W28) | 3700 | 4250 | ||
| N2 (W33) | 2950 | 3750 | ||
| N3 (W41) | 2200 | 3300 | ||
| N4 (W50) | 2050 | 3100 | ||
Prodek Spans (mm)
| Determined by wind speeds for non-cyclonic areas | ||||||
| Base Metal Thickness |
Application | Type of Span | Wind Classification | |||
| N1 (W28) | N2 (W33) | N3 (W41) | N4 (W50) | |||
| 0.35mm | Walling | Single | 2400 | 2350 | 1950 | 1600 |
| End | 2700 | 2700 | 2050 | 1800 | ||
| Internal | 3000 | 3000 | 2200 | 1800 | ||
| 0.42mm | Roofing | Single | 2600 | 2050 | 1850 | 1550 |
| End | 2800 | 2500 | 1900 | 1550 | ||
| Internal | 3200 | 2750 | 2050 | 1650 | ||
| Walling | Single | 3000 | 2700 | 2050 | 1800 | |
| End | 3500 | 3100 | 2200 | 1800 | ||
| Internal | 3800 | 3400 | 2800 | 1950 | ||
| 0.48mm | Roofing | Single | 3100 | 3100 | 2350 | 1850 |
| End | 3400 | 3400 | 2350 | 1850 | ||
| Internal | 3800 | 3800 | 2900 | 2000 | ||
| Walling | Single | 3600 | 3600 | 3100 | 2200 | |
| End | 4000 | 3900 | 3300 | 2200 | ||
| Internal | 4200 | 4200 | 3700 | 2500 | ||
| Values applicable for use with steel supports of minimum 0.95mm thickness, G550. | ||||||
Note: For Prodek span table wind capacities, design parameters and span definitions, please refer to the Cladding Wind Capacities tables and Engineering notes at the beginning of the Roofing and Walling section.
Wind Load Conversion
For domestic applications use the appropriate wind classification for the area. To read the span tables for commercial and industrial applications, select the region and category for the area, then convert it to the correct classification using table below.
| Wind Classification (domestic) | Region & Category (Commercial / Industrial) |
| N1 (W28) | Reg A, Cat 3 |
| N2 (W33) | Reg A, Cat 2.5 - Reg B, Cat 3 |
| N3 (W41) | Reg A, Cat 2 - Reg B, Cat 2.5 |
| N4 (W50) | Reg B, Cat 2 |
Wind Capacities
| Wind Capacities (kPa) | ||||||||||||||
| BMT | Span Type | Limit State | Span (mm) | |||||||||||
| 1200 | 1500 | 1800 | 2100 | 2400 | 2700 | 3000 | 3300 | 3600 | 3900 | 4200 | 4500 | |||
| 0.35mm | Single | Serviceability | 2.05 | 1.72 | 1.40 | 1.08 | 0.92 | 0.82 | 0.71 | 0.61 | 0.51 | 0.40 | 0.30 | 0.19 |
| Strength | 4.60 | 3.75 | 2.89 | 2.04 | 1.46 | 1.35 | 1.25 | 1.14 | 1.03 | 0.92 | 0.82 | 0.71 | ||
| End | Serviceability | 2.46 | 2.12 | 1.77 | 1.42 | 1.08 | 0.97 | 0.86 | 0.75 | 0.64 | 0.53 | 0.42 | 0.31 | |
| Strength | 5.38 | 4.46 | 3.54 | 2.23 | 1.69 | 1.58 | 1.47 | 1.36 | 1.25 | 1.14 | 1.03 | 0.92 | ||
| Internal | Serviceability | 2.67 | 2.31 | 1.95 | 1.59 | 1.23 | 1.10 | 0.98 | 0.85 | 0.73 | 0.60 | 0.47 | 0.35 | |
| Strength | 5.58 | 4.54 | 3.50 | 2.46 | 1.85 | 1.74 | 1.63 | 1.52 | 1.41 | 1.30 | 1.19 | 1.08 | ||
| 0.42mm | Single | Serviceability | 3.23 | 2.54 | 1.85 | 1.15 | 1.04 | 0.93 | 0.82 | 0.70 | 0.59 | 0.48 | 0.42 | 0.37 |
| Strength | 6.08 | 4.87 | 3.67 | 2.46 | 2.31 | 2.16 | 2.01 | 1.87 | 1.72 | 1.57 | 1.42 | 1.27 | ||
| End | Serviceability | 3.46 | 2.79 | 2.13 | 1.46 | 1.31 | 1.15 | 1.00 | 0.85 | 0.69 | 0.54 | 0.46 | 0.38 | |
| Strength | 6.04 | 4.79 | 3.55 | 2.31 | 2.18 | 2.05 | 1.92 | 1.79 | 1.66 | 1.53 | 1.41 | 1.28 | ||
| Internal | Serviceability | 4.08 | 3.42 | 2.75 | 2.09 | 1.43 | 1.28 | 1.13 | 0.98 | 0.83 | 0.68 | 0.65 | 0.63 | |
| Strength | 6.35 | 5.18 | 4.01 | 2.85 | 2.64 | 2.43 | 2.22 | 2.01 | 1.79 | 1.58 | 1.50 | 1.42 | ||
| 0.48mm | Single | Serviceability | 4.23 | 3.59 | 2.96 | 2.32 | 1.68 | 1.50 | 1.32 | 1.13 | 0.95 | 0.77 | 0.58 | 0.40 |
| Strength | 6.63 | 5.75 | 4.88 | 4.00 | 3.12 | 2.85 | 2.58 | 2.31 | 2.04 | 1.78 | 1.51 | 1.24 | ||
| End | Serviceability | 4.62 | 3.96 | 3.31 | 2.65 | 2.00 | 1.79 | 1.58 | 1.37 | 1.16 | 0.95 | 0.74 | 0.53 | |
| Strength | 6.54 | 5.63 | 4.71 | 3.79 | 2.87 | 2.67 | 2.46 | 2.26 | 2.06 | 1.85 | 1.65 | 1.44 | ||
| Internal | Serviceability | 4.77 | 4.13 | 3.50 | 2.87 | 2.23 | 2.02 | 1.81 | 1.60 | 1.39 | 1.18 | 0.97 | 0.76 | |
| Strength | 6.70 | 5.89 | 5.08 | 4.27 | 3.46 | 3.19 | 2.92 | 2.65 | 2.37 | 2.10 | 1.83 | 1.56 | ||
Water Carrying Capacity
| Maximum Roof Run for Drainage (m) | ||||||||
| Roof Slope | Peak Rainfall Intensity (mm / hr) | |||||||
| 150 | 180 | 200 | 250 | 300 | 350 | 400 | 450 | |
| 1° | 319 | 266 | 239 | 191 | 159 | 137 | 119 | 106 |
| 2° | 452 | 377 | 339 | 271 | 226 | 193 | 169 | 150 |
| 3° | 554 | 461 | 415 | 332 | 271 | 237 | 207 | 184 |
| 5° | 716 | 596 | 537 | 429 | 358 | 307 | 268 | 238 |
| 7.5° | 878 | 732 | 658 | 527 | 439 | 376 | 329 | 292 |
| 10° | 1016 | 847 | 762 | 610 | 508 | 436 | 381 | 338 |