Lo-Square Gutter Technical Information

Dimensions

Profile
Dimensions (mm)
A 58
B 118
C 110


Specifications

Tensile (MPa)
BMT (mm) Type Capacity (mm²) Total Cross Sect. Area (mm²)
G550 0.42 Standard 5714  
Slotted 4447 5624

Note: Calculation of effective cross sectional area ‘Capacity’ for each nominal size of eaves gutter is based on requirements of section 3.8 AS/NZS 2179.1:1994