S Gutter Technical Information
Dimensions
Profile
Dimensions (mm)
A
62
B
117
C
90
Specifications
Tensile (MPa)
BMT (mm)
Type
Capacity (mm²)
Total Cross Sect. Area (mm²)
G550
0.35
Standard
5315
6358
Slotted
4609
5622
Note:
Calculation of effective cross sectional area ‘Capacity’ for each nominal size of eaves gutter is based on requirements of section 3.8 AS/NZS 2179.1:1994