VC Gutter Technical Information
Dimensions
Profile
Dimensions (mm)
A
58
B
119
C
108
Specifications
Tensile (MPa)
BMT (mm)
Type
Capacity (mm²)
Total Cross Sect. Area (mm²)
G300
0.50
Standard
5712
5594
Slotted
4412
6893
Note:
Calculation of effective cross sectional area ‘Capacity’ for each nominal size of eaves gutter is based on requirements of section 3.8 AS/NZS 2179.1:1994