Cyclonic Good Neighbour® Fencing Technical Information

Region C

Column types

Region Category Height
  1200mm

1500mm

1800mm
C 3 & 4 1 1 2
C 2.5 1 2 2
C 1 & 2 1 2 2
1. Standard Post (Standard Panels)
2. Standard post & 1 SHS 50x50x3.0mm Post with cap (Heavy Duty Panels)

1. Cyclonic Standard Panels consist of:

2. Cyclonic Heavy Duty Panels consist of:

Footing sizes (Diameter X Depth)

Region Category Height
  1200mm 1500mm 1800mm
C 3 & 4 200 x 600 200x 700 200 x 700
C 2.5 200 x 600 200 x 700 200 x 800
C 1 & 2 200 x 600 200 x 700 200 x 800
All footings are circular and suitable for firm natural sandy clay. Increase depth 100mm for compact sand. Minimum foundation bearing capacity to be 100kPa.

Region D

Column types

Region Category Height
  900/1200mm 1500mm 1800mm
D 2 1 2 3
D 2.5 1 2 3
D 3 1 2 3
1. Standard post & 1 RHS 75x50x3.0mm post
2. Standard post & 1 SHS 75x75x3.0mm post
3. Standard post and 1 RHS 100x50x4.0mm post

Cyclonic Standard Panels consist of:

Footing sizes (mm)

Soil Type Region Height
    900/1200mm 1500mm 1800mm
Sandy D 300 x 850 300 x 1000 300 x 1150
Sandy Clay D 300 x 600 300 x 700 300 x 850
All footings are circular. For posts within a distance of 2 x Height from any free end increase footing depth by 200mm.

Note: Deemed to comply drawing number M/802/3. Darwin Building Board approved.