Roof Batten
| Material Specifications | |||
| Profile | Material Properties | 0.55mm BMT | 0.75mm BMT |
![]() |
Yield Strength | 550MPa | 550MPa |
| Coating Mass | 150g/m2 | 150g/m2 | |
| Maximum Span* | 1500mm | 1200mm | |
| Max. Sheet Roof Spacing | 1200mm | 900mm | |
| Max. Tile Roof Spacing | 330mm | - | |
| Batten Mass | 0.71kg/m | 0.97kg/m | |
| * Maximum span continuous over at least two spans. | |||
Note: Batten spacing must not exceed the maximum recommended roof cladding spans. Refer to the appropriate Stratco clading brochure for fastener and spanning details
Ceiling Batten
| Material Specifications | ||
| Profile | Material Properties | |
![]() |
Base Metal Thickness | 0.42mm |
| Yield Strength | 550MPa | |
| Coating Mass | 150g/m2 | |
| Batten Mass | 0.35kg/m | |
| Max. Span* | 1200mm (1500**) | |
| Max. Spacing | 600mm | |
| * Maximum span continuous over at least two spans. ** 1500mm maximum batten span is for WA only. |
||
Note: The maximum span and spacings shown allow for a plasterboard thickness of up to 13mm. Refer to the appropriate manufacturer's specifications for details on the ceiling installation.