Hiland Tray

Overview

Roll formed onsite with a mobile roll forming facility, Hiland Tray is an innovative product that is available in long, single lengths. Hiland Tray is snap-locked to concealed fixings via a simple clip system that is attached to the roof and wall purlins.

We can arrange installation

Versatile and Innovative Cladding

Roll formed onsite and snap-locked to concealed fixings

Mobile roll forming allows Hiland Tray to be manufactured onsite in both urban areas and remote alpine regions. It delivers a clean, high quality product with reduced handling time.

Featuring an attractive design that is available with swages (ribs) within the pan, or no swages for a clean, flat profile. Regardless of the options chosen, the flat nature of the tray means that some panning/rippling can be evident which adds to the crafted and characteristic appearance of the product.

The completed finish is smooth and uncluttered due to Hiland Tray’s innovative concealed fixing system. Hiland Tray snap-locks to a simple clip that is fixed to the roof and wall purlins.

Available Colours:

  • Bluff
  • Castle
  • Knight
  • Loch

Brochures & Installation Guides:

Brochure Selection Use & Maintenance

High Performance Cladding

The Hiland Tray profile has a high rib height of 44mm that enhances its smooth bold lines and provides greater water carrying capacity and strength for snow loading applications in alpine regions. Hiland Tray is available in 0.55mm BMT zinc/al and in a range of contemporary pre-painted colour steel options to suit any colour pallet.

Maintenance

The performance of Hiland Tray roofing and walling over time depends on its correct application and maintenance. Maintenance should be performed as often as is required to remove any dirt, salt and pollutants.

Where Hiland Tray cladding is used in severly corrosive environments, cleaning should be performed more often. It is important that screws have the same life expectancy as the Hiland Tray cladding you have specified. Packs of Hiland sheeting should always be kept dry and stored above ground level on site. If the sheets have become wet, they should be separated, wiped and placed in the open to dry.

Refer to the Stratco 'Selection, Use and Maintenance' brochure for more detailed information about the correct use and maintenance of this product.

 

Technical DetailsClick to ExpandClick to Contract

Stratco Hiland Tray Cladding Profile

Material Specifications

Material Properties Finish 0.55 BMT
Minimum 'AZ' Coating Mass (g/m²) Zinc/al & Colour 150
Mass (kg/linear metre) Zinc/al 2.71
Colour 2.75
Mass (kg/square metre) Zinc/al 5.97
Colour 6.05
Yield (square metre/tonne) Zinc/al 168
Colour 165
Tensile Strength (MPa) Zinc/al & Colour 340
Width Coverage (mm) Zinc/al & Colour 455
Sheet Tolerances (mm) Length & Width ±5 ±2
Minimum Roof Pitch Zinc/al & Colour

Maximum Recommended Spans

Maximum Recommended Spans
Span Type Roofing 0.55mm BMT (mm) Walling 0.55mm BMT (mm)
End/ Double 600 1800
Internal 900 1800

Roofing : Spans are limited based on foot traffic incidental to maintenance.
Walling: Spans are based Region A, Terrain Category 2.0 wind loading, refer to the 'Spans' table below.

Spans

Roofing Spans (mm)
Terrain Category Local Pressure KI Region A Region W
End/Double Internal End/Double Internal
1 1 600 900 600 900
1.5 600 900 600 900
2 600 900 600 900
3 600 900 560 620
2 1 600 900 600 900
1.5 600 900 600 900
2 600 900 600 900
3 600 900 600 900
3 1 600 900 600 900
1.5 600 900 600 900
2 600 900 600 900
3 600 900 600 900
Walling Spans (mm)
Terrain Category Local Pressure KI Region A Region W
End/Double Internal End/Double Internal
1 1 1800 1800 1800 1800
1.5 1800 1800 1800 1800
2 1800 1800 1470 1600
3 1320 1450 950 1080
2 1 1800 1800 1800 1800
1.5 1800 1800 1800 1800
2 1800 1800 1790 1800
3 1640 1760 1280 1410
3 1 1800 1800 1800 1800
1.5 1800 1800 1800 1800
2 1800 1800 1800 1800
3 1800 1800 1800 1800

Wind Capacities (kPa)

Wind Capacities (kPa)
BMT Span Type Linit State Span (mm)
450 600 900 1200 1500 1800
0.55mm End/Double Serviceability 5.23 3.78 3.14 2.57 2.08 1.68
Strength 6.54 4.73 3.92 3.21 2.60 2.10
Internal Serviceability 5.23 3.78 3.14 2.57 2.08 1.68
Strength 7.15 5.17 4.29 3.51 2.85 2.30

Capacities determined based on a minimum of two screws per clip into timber supports.

Engineering

Testing Systems

Stratco have developed purpose built testing equipment for the testing of cladding systems sufficient to ensure the structural adequacy of the product it produces.

Compliance

Wind Capacity Tables are based on testing for compliance with the New Zealand Metal Roof and Wall Cladding Code of Practice. Span tables have been developed by determining relevent wind pressures in accordance with AS/NZS 1170.2. Capacity tables are in limit state format.

Spans

Span tables are based on a maximum overall building height of ten metres and a 500 year design return period for strength limit state wind load assessment. Roofing spans specified are suitable for snow loading up to 2kPa in accordance with the New Zealand Metal Roof and Wall Cladding Code of Practice.

Roofing calculations are based on Cpe=-0.9 and Cpi=0.2, walling is based on Cpe=-0.65 and Cpi=0.2. Local pressures are as specified and have been considered for both strength and serviceability limit states. Roof spans take into consideration loads incidental to maintenance noting ends spans allow for foot traffic over supports only.

All pressures have been determined assuming wind loading in any direction without shielding but which is not affected by topography (i.e. Mt=1.0). Allocated spans do not allow for Lee Zones, for areas within these zones, utilise the wind capacity tables to calculate spans based on the relevant allowance for Lee Multipliers.

Additional engineering advice can be obtained from Stratco if any design parameters vary from those indicated above.

Design Considerations

Hiland Roofing and Walling has a 455mm cover with a 0.55mm BMT material thickness. The minimum allowable roof pitch is 3°.

 

Installation DetailsClick to ExpandClick to Contract

Fixing Recommendations

Hiland Tray sheets should be laid into the prevailing wind and clip neatly onto the preceding roof sheet. The Hiland Tray clips should be fixed within the recommended support spacings.

Due to the seam height, flashing turn downs into the pan of Hiland Tray sheeting should always be notched around the rib to provide maximum weather tightness.


Laying Procedure

Laying Direction →

← Prevailing Wind

Stratco Hiland Tray Cladding Laying


Installation Details

Concealed Clip Fixing

  • Stratco Hiland Tray Cladding Fixing
  • Stratco Hiland Tray Cladding Fixing
  • Stratco Hiland Tray Cladding Fixing

Fixing to Timber

Two 10 x 30mm wafer-head timber fixing screws (square drive recommended) per clip. Clips located at every sheet overlap and sheet edges at each timber support. Timber supports to be 100 x 50mm planer gauged and minimum MGP10 or F5 grade.

Walking on Hiland Tray

When walking on Hiland Tray roofing, walk over the purlins to avoid damage to the sheeting. Wear flat rubber soled shoes and walk flat footed in the pans only. Walking on end spans is restricted explicitly to over the end span purlins with no access allowed directly on end spans due to potential sheet damage.

 